Description
Similar to #1841 for the OSDs, the MDS should reconnect to a different monitor if its beacons go too long without getting acked. This will prevent unfortunate scenarios where a standby MDS doesn't discover it needs to go active until the messenger timeout is exceeded! (See Karoly Horvath's email thread "how can I achieve HA with ceph?".)
- Subject changed from The MDS should time out slow monitors to mds: should time out slow monitors
- Translation missing: en.field_position set to 30
- Translation missing: en.field_story_points set to 2
- Translation missing: en.field_position deleted (
30)
- Translation missing: en.field_position set to 30
- Translation missing: en.field_position deleted (
30)
- Translation missing: en.field_position set to 2
- Status changed from New to Resolved
This was actually very easy to do. Ripping out the utterly useless beacon_kill code was actually a larger diff!
Errm, commit:ac9b2d092f1f075621f30f77cdbb49bdf35b9ae5