mds: should time out slow monitors

Added by Greg Farnum over 12 years ago. Updated over 7 years ago.

Status:
Resolved
Priority:
Normal
Assignee:
Category:
-
Target version:
-
% Done:

0%

Source:
Tags:
Backport:
Reviewed:
Affected Versions:
Component(FS):
Labels (FS):
Pull request ID:

Description

Similar to #1841 for the OSDs, the MDS should reconnect to a different monitor if its beacons go too long without getting acked. This will prevent unfortunate scenarios where a standby MDS doesn't discover it needs to go active until the messenger timeout is exceeded! (See Karoly Horvath's email thread "how can I achieve HA with ceph?".)